Electron beam oscillations in ELV-type accelerators, their diagnostics and suppression method

Authors

  • E.V. Domarov
  • D.S. Vorobev
  • Y.I. Golubenko
  • A.I. Korchagin
  • N.K. Kuksanov
  • R.A. Salimov
  • S.N. Fadeev
  • V.G. Cherepkov
  • I.K. Chakin

DOI:

https://doi.org/10.31489/2024ph4/20-26

Keywords:

electron accelerator, ELV, focused electron beam, electron beam oscillations, electron beam oscillation suppression method, electron beam oscillation diagnostics

Abstract

In the article a method for diagnosing electron beam oscillations in ELV-type accelerators associated with the penetration of a transverse magnetic field from the primary and secondary windings into the accelerating tube was described. A method for suppressing these oscillations was developed and tested using the ELV-8 accel- erator with an extraction device capable of extract a focused electron beam into the atmosphere. After sup- pressing the oscillations, it was possible to extract a focused electron beam with a power of 100 kW into the atmosphere and increase the service life of the diaphragms.

Downloads

Published

2024-12-28

Issue

Section

PHYSICS OF THE CONDENSED MATTER

Received

2024-12-28